With the factory-prepared SD card, connect, power on and use H102 directly. No image download or card writing is needed. If you supply your own SD card, prepare it first, then follow the same startup and reception steps.
This guide uses a Linux PC as the reception client and the device services installed on H102. Windows is used only when generating new ADRV9002 profiles.
For a blank card use deployment. Administrators can check updates. Developers can continue to GNU Radio.
The reference network receiver uses Ubuntu 22.04 x86_64, Python 3.10+, a Qt desktop and network-enabled libiio 0.x. Run these read-only checks on the PC, then follow first reception to install into the application’s own virtual environment.
Linux PC · Host preflight. Run as shown and check the reported OS and tools.
uname -m
cat /etc/os-release
python3 --version
iio_info -h
If iio_info is missing, install the libiio utilities listed in this guide. With the actual device IP run iio_info -u ip:DEVICE_IP to check discovery. Then verify a live IQ capture in the GUI. Run .venv/bin/python -m pip check after installation. To roll back, close the GUI and launch the retained previous GUI directory and its own virtual environment. Retire the new application directory after checking rollback. Shared Qt and libiio packages are managed by the host administrator. GNU Radio 3.10.12.0 and optional FT601 USB are separate workflows.
| Your card | Start here | Write an image? |
|---|---|---|
| Factory-prepared SD card with the system installed | A: use the factory card | No |
| Your own MicroSD card | B: prepare your own card | Yes |
| Item | Requirement and purpose |
|---|---|
| H102 | Rev.B with the matching 1.2.1 image |
| Own card and reader (path B only) | A 32 GB or 64 GB MicroSD card is recommended; actual capacity must be at least 11,823,742,976 bytes. See SD card requirements |
| Power | Connect the Type-C power adapter supporting 12 V with a rated output above 12 W at 12 V, and a matching cable to D4; check the connection |
| Ethernet | Connect to a network reachable from the PC; use DHCP or the provisioned static fallback |
| USB3 data cable | SuperSpeed-capable, connected to the FT601 data port; optional for the first network reception |
| UART0 (optional) | Use to find the IP or diagnose startup; 115200 baud, 8N1, no flow control |
| GNSS antenna | Required for valid UTC timestamps; connect to the dedicated GNSS port |
| RF connection | An RF source is optional for the first receive check; see hardware reference before any loopback |
Use Ubuntu 22.04 x86_64, Python 3.10+, a Qt graphics desktop and libiio 0.x with networking for the Linux reception client. For first use, connect the PC and H102 to the same router or switch. The supplied GUI package supports Linux; Windows TES is not the reception client.
The factory card already contains the matching system and device services. No card reader, image download, card writing or device-service installation is needed.
Verify the image, split files, target media and readback · Deployment tools and examples
With H102 powered off, confirm the factory card or your prepared card is fitted and keep the factory SD boot setting. Connect Ethernet to D3 and the matching Type-C power adapter/cable to D4, supporting 12 V with a rated output above 12 W at 12 V. Check connections, then power on. A newly prepared card initializes identity and expands storage on first boot and may restart automatically; wait for the system and services to become ready.

Panel identifiers: D3 Ethernet, D2 debug console, D4 specified supply. Do not identify an unlabeled opening as the SD slot from this drawing.
Follow the markings on the actual slot; the panel drawing does not specify card contact orientation. Check the direction if resistance is felt and do not force the card. First network reception needs neither D1 USB3 nor a TX/RX loopback.
Check the router’s DHCP client list and identify this H102, or use an address explicitly supplied with the delivery. Do not copy an example IP from this page.
An own card written with r3’s default network settings tries DHCP, then falls back to 10.168.1.199/24 without a lease. For a direct connection, the PC can use an unused 10.168.1.200/24. Use the actual delivered network settings for a factory card. Multiple devices must not share one fallback address. See network setup.
If the IP is unknown or startup needs inspection, use console and system checks below. Factory-card users with a confirmed IP can connect the GUI directly, without SSH login or card-writing checks.
The delivered GUI supports a Linux desktop, Python 3.10 or later, Qt-compatible graphics and libiio 0.x with its network backend. The commands below follow the package's Ubuntu installation path. They do not install anything on H102. Windows/macOS installation is outside this package's supported setup.
hawk-h102-iio-gui-0.8.1-source.zip from matching downloads, and compare its SHA-256 with that table. The automatically generated GitHub Source code ZIP is a different file.GUI_ZIP to the actual downloaded file; use a new extraction directory if this version is already present.Linux PC · Run in the tool or project directory named here; set paths to the actual installation and files.
GUI_ZIP="$HOME/Downloads/hawk-h102-iio-gui-0.8.1-source.zip"
sha256sum "$GUI_ZIP"
mkdir -p "$HOME/LogicRF/hawk-h102/apps"
python3 -m zipfile -e "$GUI_ZIP" "$HOME/LogicRF/hawk-h102/apps"
cd "$HOME/LogicRF/hawk-h102/apps/hawk-h102-iio-gui-0.8.1"
sudo apt install python3-venv libiio0 libgl1 libegl1 libopengl0 \
libglib2.0-0 libfontconfig1 libdbus-1-3 libxkbcommon-x11-0 \
libxcb-cursor0 libxcb-icccm4 libxcb-image0 libxcb-keysyms1 \
libxcb-render-util0 libxcb-xinerama0 libxcb-xkb1 libxcb-shape0 \
libx11-xcb1 fonts-noto-cjk
python3 -m venv .venv
.venv/bin/python -m pip install -r requirements.txt
.venv/bin/python -m pip check
requirements.txt contains the package's supported dependency ranges; requirements.lock records its development environment. The native libiio shared library is required: installing a Python package named iio is not a substitute. Run the GUI in a graphical desktop session.
Installation check: Start the command below in a graphical desktop and confirm that the GUI window opens before connecting to H102. pip check checks Python dependencies, not Qt/OpenGL/XCB system libraries; see the host installation guide for the complete requirements.
From that application directory, launch with the actual IP:
Linux PC · Use the connected device’s actual IP or URI and your local installation paths.
H102_IP=192.168.1.100
bash ./launch.sh --host "$H102_IP" --language en

Offline control locations: expand Connection, replace the example IP and choose Connect / refresh.

Select independent RX/TX, 4 MSPS / 2 MHz and RX1, then apply. A selected list value is not an actual device readback.
| Step | Action | What to check |
|---|---|---|
| Connect | Expand Connection, check the IP and choose Connect / refresh | The status reports Connected, with the actual profile/carrier readback. No Linux password prompt is expected |
| Configure | In RX configuration, select Independent RX / TX, 4 MSPS / 2 MHz, and RX1; choose Apply profile | Wait for completion. Actual profile is 4msps-2mhz; changing profiles can take more than 20 seconds |
| Set frequency | Enter the intended receive frequency in the large MHz control and press Enter, or point at a digit and scroll | The readback below the control confirms the applied carrier. For a noise-only check, no RF source is needed |
| Select reception | Choose Live RX, Manual stop, and Normal IQ | Do not select the digital RAMP16 test source when expecting antenna signals |
| Start | Choose the ▶ RX icon | The status changes to Live RX and RX1 spectrum/IQ updates. An unconnected input normally shows noise |
| Stop | Choose the same RX control, now the stop icon | Wait for RX ended · Restored; keep any failure/recovery message before retrying |
| Finish | Choose Disconnect before handing the device to another application | No receive/transmit session remains owned by this GUI |

Historical device screen: a 10-second dual-RX session at 4 MSPS / 2 MHz has ended, with RX1 displayed. Use it to locate spectrum, waterfall, I/Q and completion status. Follow the table's single-RX1 setup for your first exercise; do not copy every displayed value.
Use a suitable receive antenna to observe an RF signal. First reception needs neither a TX cable nor an RF loopback. The save icon exports only the latest IQ block; use the separate recording control for a whole recording. See data streaming for formats and integrity checks. A moving plot alone is not proof of lossless recording.
For programming, start with the read-only C++ and Python examples, then use the IIO interface guide for data programs. A finite snapshot does not establish long-term sample continuity.
| Stage | What to observe | Meaning |
|---|---|---|
| System boot | Actual IP is known, device services are ready and the GUI can connect | Successful card writing does not include this check |
| Application connection | Connected state and actual profile/carrier readback | Pressing Connect alone is insufficient |
| First reception | RX1 display updates and stop reports restoration | An input without a signal source normally shows noise |
| Recording | Expected files, sample counts and sizes; check errors and overflows | Continue with recording integrity; moving plots do not replace these checks |
| Recovery | Disconnect/reconnect works and actual settings can be read | Then hand the device to another application |
This is basic onboarding. RF power/response, timing accuracy and long-term continuity require their corresponding test conditions.
For carrier tuning or an existing rate/bandwidth, use built-in configurations. To add a combination, follow Windows ADRV9002 profile generation: obtain the matching SDK and request templates, generate offline and import.
End acquisition/playback and release buffers and USB sessions before running sudo poweroff on H102. Disconnect power or remove the card only after normal shutdown. Continue with configuration or data streaming.
Use this section to find an unknown IP, investigate startup or inspect your own prepared card. It is not required for each use of a factory card.
Connect the UART/USB2 port to the PC using a USB data cable. This console is separate from the USB3.0 FT601 IQ port. On Linux, inspect the actual serial entries with ls -l /dev/serial/by-id/; compare before and after attaching the console cable when several serial devices are present. Select the entry for this H102, rather than assuming /dev/ttyUSB0.
Use a serial terminal set to 115200 baud, 8 data bits, no parity, 1 stop bit, no hardware or software flow control. For example, on an Ubuntu PC, an administrator can install picocom once and open the selected console:
Linux PC · Local serial terminal. Use the USB serial device detected on this PC.
sudo apt install picocom
UART_DEVICE=/dev/serial/by-id/replace-with-the-actual-h102-console
sudo picocom --baud 115200 --databits 8 --parity n --stopbits 1 --flow n "$UART_DEVICE"
Replace the path before running. Keep this terminal open when powering H102 on. Exit picocom with Ctrl+A, then Ctrl+X; closing the terminal does not shut H102 down. Only one program should open the same serial port. /dev/ttyPS0 is the console name inside H102, not the serial device to select on the PC. If no serial device appears, check the UART/USB2 connection and data cable before proceeding.
| Stage | Expected identity |
|---|---|
| FSBL | Release 2024.1, Boot mode is SD |
| Default boot | H102-LOGICRF-SDK1-RUNTIME-WIRE |
| FPGA / kernel | H102-BIT-LOAD-DONE, H102-FIT-LOAD-DONE |
| ADRV9002 | API version: 68.21.6 successfully initialized |
| Login | logicrf login: |
Completion check: logicrf login: appears and login works. A power LED or FPGA heartbeat alone does not establish Linux/service readiness. Wait through any first-boot expansion restart until the final login prompt.
The default username and password are both logicrf; the hostname is logicrf. Change the password after first login according to your site policy. Use the actual DHCP lease, or 10.168.1.199 for the default r3 fallback; check each device separately and avoid duplicate fallback addresses.
H102 shell · Run after SSH or serial login. Use the interface and configuration names on this unit.
ip -4 address show dev eth0
uname -r
cat /proc/sys/kernel/random/boot_id
sudo h102-config-sdk1 status
systemctl --failed --no-pager
The expected kernel is 6.6.0-h102-sdk1-candidate-calfix1-regbounds1-sharedlo1, with default configuration 40msps-20mhz. Status includes the current boot, actual parameters for all four channels and idle information.
Look for the inet address under eth0. For inet 192.168.1.100/24, enter 192.168.1.100 in the GUI without /24. If no IPv4 address is present, check the D3 Ethernet cable, allow startup and the DHCP timeout to finish, and confirm which network mode was used to write the card before continuing.
Completion check: record this device's actual IP, read its configuration status and resolve failed services. See troubleshooting if a check fails.
Replace the example address with the actual IP. Install libiio tools on the PC, then run:
Linux PC terminal · IIO discovery. Install the host tools, then replace the address with this H102’s actual IPv4 address. Run the following checks on the PC.
Linux PC · Use the connected device’s actual IP or URI and your local installation paths.
sudo apt install libiio-utils
H102_IP=192.168.1.100
iio_info -u "ip:$H102_IP"
iio_attr -u "ip:$H102_IP" -d h102-profile-control active_info
Optional SSH login · open a separate PC terminal. Replace the example address with the unit address and verify the host fingerprint. The prompt after login belongs to H102. The board status commands are listed above. Use exit to return to the PC.
Linux PC · New terminal. Verify the host key and enter the device management IP.
ssh logicrf@192.168.1.100
Discover h102-profile-control, adrv9002-phy and the RX/TX sample devices. The software control device has no sample buffer; IQ comes from the matching sample device.
Use new-device deployment tools when preparing multiple own cards. Complete writing/readback, safe ejection, startup and application checks for each card. Ordinary use of the factory-prepared card does not require this writing workflow.