STREAM captures and records IQ from fixed Eagle R508 ADC groups. When STREAM is listed in your delivery manifest, confirm that STREAM is active and ready in ULMUS Device Overview. Use the SDK, DAQ and desktop software versions supplied with that delivery. Connect and sign in · Receiving server setup
The ADC sampling rate is fixed at 5 GSPS. The profile selects RFDC decimation, digital filtering and the output IQ rate per channel. IQ rates below are complex samples per second. The 8, 16 and 32 MHz entries give nominal filter bandwidth. For bypass profiles, use the delivered passband specifications.
| Profile | Nominal bandwidth / IQ per ADC | RFDC decimation / filter | ADC groups | Max. IQ rate |
|---|---|---|---|---|
BW8M_10MSPS |
8 MHz / 10 MSPS | 40 / Enabled | First four, last four or all eight | 2.56 Gb/s |
BW16M_20MSPS |
16 MHz / 20 MSPS | 20 / Enabled | First four, last four or all eight | 5.12 Gb/s |
BW32M_40MSPS |
32 MHz / 40 MSPS | 10 / Enabled | First four, last four or all eight | 10.24 Gb/s |
IQ125MSPS |
— / 125 MSPS | 40 / Bypass | First four, last four or all eight | 32 Gb/s |
IQ250MSPS |
— / 250 MSPS | 20 / Bypass | First four or last four | 32 Gb/s |
IQ500MSPS |
— / 500 MSPS | 10 / Bypass | First four or last four | 64 Gb/s |
IQ1000MSPS |
— / 1 GSPS | 5 / Bypass | An aligned pair | 64 Gb/s |
IQ2500MSPS |
— / 2.5 GSPS | 2 / Bypass | One channel | 80 Gb/s |
Budget raw IQ as per-channel IQ rate × channels × 32 bits, then account for packet and storage overhead. Read stream.profile.list for supported profiles and masks. Verify receiver support and throughput with the matched SDK/DAQ and your server. Begin with a bounded 8 MHz recording and check its valid byte count.
| ADC labels | Device JSON-RPC channel_mask |
SDK and DAQ adc_channels |
|---|---|---|
| ADC1–4 | 15 (0x0F) | [0,1,2,3] |
| ADC5–8 | 240 (0xF0) | [4,5,6,7] |
| ADC1–8 | 255 (0xFF) | [0,1,2,3,4,5,6,7] |
Before capture, check availability in the device's stream.profile.list, the DAQ manifest and your delivery's host receive specifications.
The data plane uses 8192-byte UDP payloads. Configure MTU 9000 along the receive path as described in the server deployment guide. Use V1 with one flow for the first short capture. A flow is a UDP receive stream. The flows jointly carry the selected ADC group.
| Mode | UDP payload | Flow counts | Samples per channel per datagram |
|---|---|---|---|
| V1 header | 64-byte application header + 8128 bytes of IQ | 1, 2, 4, 8 | 508 for four ADCs, 254 for eight |
| Headerless | 8192 bytes of IQ | 1 | 512 for four ADCs, 256 for eight |
Merge multiple V1 flows by global packet sequence before evaluating packet continuity. For headerless recordings, preserve the acquisition settings and receive order. Source sample loss cannot be derived from headerless bytes. When using device time, check the task's synchronization status and the scope of the delivered timing verification. Wire format and fields
Start with the first recording in DAQ Web. It uses 8 MHz / 10 MSPS, ADC1–8, one V1 stream and a limit of one 128 MiB segment. Check receive, write and commit before switching to another profile.
In DAQ Web on the receiving server, use server.status and device.status to check the delivery-matched STREAM service, device availability and idle task state. Start a new task using the DAQ parameters. Watch receipt and save counters, errors and available space in task status. After stopping, wait for the host to finish draining and commit the files. When using DAQ or Workbench, DAQ owns the capture lifecycle.
Your application may configure the device over JSON-RPC on the trusted management network and receive UDP separately on the 100G network. Prepare every receive endpoint before starting device transmission. Then stop the device sender before finalizing the host files. With the SDK, use the supplied STREAM profile client and the decoder for the selected packet format. STREAM API · DAQ Web walkthrough
task.json and the completed files. Use its profile, sample rate, physical channel order, header length, flow count and valid byte lengths. Segment size and preallocation describe storage capacity.| Symptom | Check |
|---|---|
| STREAM or the profile methods are missing | Check the active app, release identity and runtime manifest in ULMUS. Use the matching host packages. |
| A 250 MSPS request is rejected | Select the first or last four ADCs. Stop the current task and read back the profile. |
| The profile is configured, with no recording | Configuration leaves capture stopped. Start with one task owner and check the data link, receive ports and mounted volume. |
| Packets arrive faster than files are written | Check MTU, port binding, DPDK receive counters, the capture volume and sustained disk throughput. Compare with a short 8 MHz / 10 MSPS task first. |