This chapter explains hardware concepts needed by the software. Use the delivered specifications and connector drawings for the exact hardware revision for positions, supply voltage/polarity, maximum RF input and mechanical dimensions. Do not wire from a product name or abstract homepage diagram.
Record the unit and PCB revision from the label. Check the assembly sheet for standard, optional, configuration-dependent and reserved connectors, then match each panel label to the delivered drawing. Request the controlled drawings · See the channel map.
Applies to Eagle R508. Clock connector designations refer to YDT6201 V1.0. Reference checked on 2026-11-19. Match the enclosure label and the delivered drawing revision before connecting equipment.
| Item | Identified interface | Obtain before connecting |
|---|---|---|
| RF input and output | Eight RF-ADC receive channels, panel labels and delivery channel map | Front-end frequency range, impedance, input power and DC limits. Output features depend on the delivered variant |
| Management and data | Dedicated management Ethernet and QSFP28 100GbE acquisition link | Media, modules and network settings. Confirm recording throughput for the host and storage |
| Reference | J21 external SYSREF in, J22 reference out, J23 external 10 MHz in | Input/output levels, termination and limits from the revision-specific interface table |
| Power | Unit rating label and supplied power source | Connector, pinout, polarity, input range and rated current |
| Mechanical and cooling | Model-specific installation drawing and airflow guide | Dimensions, mounting holes, clearance, airflow and environmental conditions |
Give product support the model, label revision and planned connections to obtain the matching installation drawing and interface ratings.
Workbench ADC1–8 correspond to DAQ logical indices 0–7. SAM defines four spectrum channels. Locate physical sockets using the drawing for your revision.
Management Ethernet carries Web, RPC and maintenance. UDP acquisition uses a separate high-speed data link. Use connectors, modules and cables supported by the hardware revision. A 100G link does not establish that every acquisition or disk workload achieves 100 Gb/s.
Before connecting DAC to an instrument, calculate maximum output and permitted instrument input. Add appropriately rated attenuation if needed, keep output off and start at low amplitude. Do not connect directly without known limits/protection.
STREAM profiles produce per-channel IQ rates downstream of the 5 GSPS ADC. Filter bandwidth and bypass IQ sample rate are listed separately. Channel and bandwidth settings
Select internal/external reference using the delivered clock profile, read actual state and perform the application's synchronization procedure. Do not substitute LMK/LMX settings from another application or infer register equivalence from filenames.
PLL lock, RFDC MTS, sustained reception and absolute sample time require separate verification. Check electrical requirements and the clock profile before external reference/SYSREF use.
Page 29 of the YDT6201 V1.0 design distinguishes these three coaxial clock interfaces. This table identifies functions for that revision; it is not a connector-position drawing, amplitude-rating table or pinout for another revision.
| Reference | Direction | Function | Constraint |
|---|---|---|---|
| J21 | Input | External SYSREF | Not a 10 MHz reference input; check signal form and synchronization setup |
| J22 | Output | Reference-clock output | Defined by the actual clock profile; do not connect another output source |
| J23 | Input | External 10 MHz reference | Separate from internal TCXO; confirm reference selection and delivered level requirements |
The page labels the internal TCXO as 10 MHz, the LMK04828 as clock distribution/synchronization, and CVHD-950X-100 as an associated oscillator. Nominal component labels do not prove installed BOM, level margin, PLL lock or product frequency accuracy. Recheck lock/synchronization after a reference change.
Publicly reviewed supply/RF limit tables, connector pinouts and mechanical drawings are not included in this edition. Obtain the corresponding revision's materials delivered with the device. This page supplies no guessed values and does not publish complete PCB/SCH files.
This is a functional diagram, not physical connector positions. Do not infer missing limits or dimensions from PCB appearance or another revision's candidate drawings.
| Link | Purpose | Before connecting | Possible symptom of error |
|---|---|---|---|
| Power | Start the device/system | Label, supplied adapter, polarity/voltage/current and switching procedure | No boot or repeated resets; do not diagnose by trying different voltages |
| Management network | Web/control/status | Port, IP, subnet/route | Web unreachable does not establish 100G FPGA failure |
| 100G data | High-speed UDP | Modules/cables, link, destination and MTU9000 | Control works but packets absent or erroneous |
| ADC RF input | Sample the signal | Correct connector, ratings, frequency, splitter/attenuation | Missing tone, clipping or overload; check limits first |
| DAC RF output | Instrument/load | Output off, instrument maximum input and attenuation | Overload/damage; digital gain is not dBm |
| Reference/SYSREF | Application synchronization | Direction, frequency, levels and clock profile | Initialization/lock/sync errors; do not interchange different functions |
Record loss, cable and physical-channel mapping for each branch. Generator-panel level is not each ADC-port level. Start with low amplitude/few channels and check for overload before increasing. Connecting eight branches does not qualify all channels' absolute amplitude/phase.
Use the delivered default clock configuration. Do not edit LMK TXT or select an unknown reference just to obtain a lock indicator. Establish requirements and revision-specific wiring before configuring external reference, SYSREF or inter-device synchronization. Internal operation does not qualify the external-reference or UTC/PPS path.
Use technical support or your order's delivery contact. Provide the serial number, PCB/enclosure revision and order reference; check identity on the label and Web About page. Do not send passwords, tokens or private keys. Ask the delivery provider to confirm each item below. Do not wire from another board's photograph when revision-matched power/interface information is missing.
| Attachment | Required information | Receipt check |
|---|---|---|
| Labelled panel/board photographs | Management port, 100G port, power inlet, ADC/DAC and clock connectors | Same hardware revision; readable labels |
| SD installation drawing | Slot location, contact orientation, insertion direction and power-off procedure | Identifies this device, rather than inferring location from the imaging tutorial |
| Power and RF ratings | Approved supply, voltage/polarity/current, ADC input limits, DAC output and protection | Revision, units and limiting conditions stated |
| Channel/reference mapping | Physical connectors to logical channels; direction and electrical levels | Matches the application and cable labels |
| Serial connection instructions | Connector, cable/electrical standard, baud rate and remaining serial parameters | Do not connect an unknown USB serial adapter without confirmed levels |
| Mechanical/installation material | Mounting dimensions, cooling and operating environment | Obtain the enclosure-matched attachment; complete PCB/SCH is not public |
This is a delivery checklist, not a claim that this page contains physical photographs or electrical ratings. Functional topology diagrams do not replace insertion/wiring drawings.
STREAM Workbench shows ADC1–8. DAQ adc_channels uses zero-based indices. Packet IQ follows ADC order within the selected group. Locate the physical sockets using the delivered panel drawing.
| Workbench / ADC | DAQ API | Group mask |
|---|---|---|
| ADC1 | 0 | 0x0F |
| ADC2 | 1 | 0x0F |
| ADC3 | 2 | 0x0F |
| ADC4 | 3 | 0x0F |
| ADC5 | 4 | 0xF0 |
| ADC6 | 5 | 0xF0 |
| ADC7 | 6 | 0xF0 |
| ADC8 | 7 | 0xF0 |
Use 0xFF for all eight when the active application and profile support the group.