This page describes interface functions in the Osprey T808. Before connecting equipment, check the hardware revision, connector labels, electrical requirements and delivered wiring diagram. Matching connector shapes do not imply interchangeable functions.

| Interface | Purpose and connection requirements |
|---|---|
| Eight ADC SMP inputs | Nominal 50 Ω, AC-coupled RF reception. Use the delivered input-power limits and passband specification |
| GNSS | Antenna input; active-antenna supply voltage and current must match the configuration |
| REF10 | External 10 MHz frequency-reference input; it carries no UTC date or second number |
| PPS | Second-edge input; absolute time also requires correctly associated time messages |
| IRIG-B | DCLS digital time-code input; amplitude-modulated IRIG-B requires external demodulation |
| TRIG | Acquisition or transmit event input |
| SYNC | Controlled synchronization-event input, separate from routine triggers and RF SYSREF |
PPS, TRIG, SYNC and IRIG-B are digital-event interfaces. Do not treat them as 50 Ω RF inputs. Match logic levels, pulse widths, edges and reference grounds to the delivered electrical specification. The 10 MHz port is an input. Use a suitable reference distributor for multiple modules rather than connecting terminated inputs in parallel.
| Interface | Integration purpose |
|---|---|
| OCuLink | Host PCIe ×4 Endpoint connection; not board power, sampling-reference or PPS distribution |
| QSFP28 | High-speed transport; match modules, cables, FEC and host NIC to the delivery |
| Dual RJ45 | PS networking and management; the BMC has a 100 Mb/s attachment, regardless of the external Gigabit ports |
| USB Type-C data | Device role connected to a computer; USB networking requires matching software |
| USB debug serial | Maintenance and debugging; separate from the data and power ports |
The host must support the required PCIe topology. A mechanical ×16 slot alone does not establish four-way ×4 bifurcation support. For multiple modules, verify identities, link training, reset and concurrent DMA separately.
Use the nominal 24 V DC supply and branch protection specified for the delivery. Select board power inputs according to the matched arrangement rather than paralleling arbitrary sources. The 60 W value is a board design budget. Include expansion cards, reference distribution, fans, conversion losses and environmental derating in system power calculations.
The 180 ×120 mm outline excludes connector mating space, coaxial bend radii, cooling, expansion cards and insulation. Preserve the required airflow. The insertion-style multi-module arrangement assumes shutdown and power removal for maintenance; it does not establish hot-swap or blind-mating compatibility.